Type 651
Serial RS-232 Connector
|
NOTE:
The MKS RS-232 Serial communications cable (CB651-10-10) must be used for the 9 pin Serial Interface connector. Unlisted pins on this connector are not compatible with the Type "D" 9 pin, industry standard cable.
|
|
Pin
|
Description
|
| 1 |
No Connection |
| 2 |
Transmit Data |
| 3 |
Receive Data |
| 4 |
No Connection |
| 5 |
Digital Ground |
| 6 |
Reserved |
| 7 |
Reserved |
| 8 |
No Connection |
| 9 |
No Connection |
I/O Connector
| 1 |
PLO relay #1 - NC contact |
| 2 |
PLO relay #1 - NO contact |
| 3 |
PLO relay #2 - NC contact |
| 4 |
Digital Ground |
| 5 |
Learn system (Low) |
| 6 |
Hold both pins 6 and 11 Low to select analog set point with position control |
| 7 |
Softstart (Low) |
| 8 |
Close valve (Low) |
| 9 |
Reserved |
| 10 |
Analog set point divided by 10 |
| 11 |
Hold only pin 11 low to select analog set point with pressure control Hold both pin 6 and 11 low to select analog set point with position control |
| 12 |
Select set point E (Low) |
| 13 |
Select set point D (Low) |
| 14 |
Select set point C (Low) |
| 15 |
Select set point B (Low) |
| 16 |
Select set point A (Low) |
| 17 |
Reserved |
| 18 |
Reserved |
| 19 |
Valve open status (Hi=open) |
| 20 |
PLO relay 1 - common contact |
| 21 |
PLO relay 2 - common contact |
| 22 |
PLO relay 2 - NO contact |
| 23 |
Valve closed status (Hi=closed) |
| 24 |
Reserved |
| 25 |
Remote zero (Low) |
| 26 |
Stop valve (Low) |
| 27 |
Open valve (Low) |
| 28 |
PLO #2 status (Low=out of limit) |
| 29 |
PLO #1 status (Low=out of limit) |
| 30 |
+15 V Output |
| 31 |
-15 V Output |
| 32 |
Power Ground |
| 33 |
+ Set point Input |
| 34 |
- Set point Input |
| 35 |
Analog Ground |
| 36 |
Pressure output voltage |
| 37 |
Position output voltage |
Transducer Connector
|
Pin
|
Description
|
| 1 |
+ 15 V Supply |
| 2 |
+ Pressure Input |
| 3 |
Reserved |
| 4 |
Reserved |
| 5 |
Power Ground |
| 6 |
- 15 V Supply |
| 7 |
+15 V Supply |
| 8 |
Reserved |
| 9 |
-15 V Supply |
| 10 |
Reserved |
| 11 |
Digital Ground |
| 12 |
- Pressure Input |
| 13 |
Reserved |
| 14 |
Reserved |
| 15 |
Chassis Ground |
Download a PDF version of this file.
Note:
This information is subject to change without notice.
Need help?
Contact MKS Instruments by sending an email to MKS or call 800-227-8766 or 978-645-5500 (outside the USA).
© 2008 by MKS Instruments