Technical Information

Application Notes

CAD Drawings

Data Sheets

EDS/GSD Files

FAQ`s

Gas Correction Factors

Installation/Setup Files

Links

Manuals

Pin-Outs

Process Solutions

Software Drivers

Standards Compliance

Technical Papers

Videos

Type 250

Valve Connector
Pin Description
1* Voltage High
2* Voltage Low (Chassis)
3 Chassis Ground
4 No Connection
5 No Connection
6** Current High
7** Current Low
8 No Connection
9 Chassis Ground
* For Piezoelectric type valves
** For Solenoid type valves

Input Connector
1 (+) Pressure Input
2 Reserved
3 D.C. signal Output (0 to 10 VDC)
Duplicate of transducer signal
4 Signal Return (Analog Ground)
5 Reserved
6 Reserved
7 Reserved
8 (-) Input (Connect to Analog Ground (Pin 12) at input source)
9 Reserved
10 Reserved
11 +/- 15 V Output
12 Power Supply Ground (Analog Ground)
13 -15 V Output
14 Chassis

Interface Connector
Pin Description
1 (+) Set Point
2 Reserved
3 Digital Ground (Common for Manual and Close)
4 Manual (Connect to Pin 3 to put in Manual)
5 Close (Connect to Pin 3 to put in Close)
6* Controller Output (0 to 10 Volts - used for pump speed control)
7 Reserved
8 (-) Set Point (Connect to analog ground (Pin 12) at input source)
9* Pressure Control Signal (PCS) (10 V Full Scale)
10* D.C. Signal (0 to 10 Volts) Duplicate of transducer signal
11 +15 V Output
12 Power Supply Ground (Analog Ground)
13 -15 V Output
14 Chassis
* Items are on standard and DVM models

Download a PDF version of this file.

Note:

This information is subject to change without notice.

Need help?

Contact MKS Instruments by sending an email to MKS or call 800-227-8766 or 978-645-5500 (outside the USA).

MKS Instruments, People's Republic of China  MKSInstruments, United Kindom  MKS Instruments, Taiwan  MKS Instruments, Germany, GmbH  MKS Instruments, Japan  MKS Instruments, France  MKS Instruments, Korea 
en español supplier support    |      MKS Logo Shop    |      privacy policy    |      legal    |      site map

© 2008 by MKS Instruments