Type 1253

J2 Power Connector
Pin Description
Also connects to J1 Pin
1 +15 to +30 VDC Power Supply Input 12
2 Power Supply Common 11
3 -15 VDC (external supply to transducer) 21
4 Pressure Signal Common 13
5 Pressure Signal Input 20
6 Limit-switch Common 24
7 Open Limit-switch Output 22
8 Close Limit-switch Output 23
9 Chassis Ground 1 and 25

J1 Input Connector
Pin Description
Also connects to J2 Pin
1 Chassis Ground 9
2 TX (RS-232)
3 RXD (RS-232)
4 No Connection
5 No Connection
6 No Connection
7 Digital Common
8 +5 VDC Output (powers portable terminal)
9 Set Point Input (Hi side)
10 Set Point Return (Lo side)
11 Power Supply Common 2
12 +15/30 V Power Supply Input 1
13 Pressure Signal Common (Lo) 4
14 No Connection
15 No Connection
16 No Connection
17 No Connection
18 Manual Close Command Line
19 Manual Open Command Line
20 Pressure Signal Input (Hi side) 5
21 -15 VDC (External supply to transducer) 3
22 Open Limit-switch Output 7
23 Close Limit-switch Output 8
24 Limit-switch Common 6
25 Chassis Ground 9

J3 Valve Connector
Please consult factory

Download a PDF version of this file.

Note:

This information is subject to change without notice.

Need help?

Contact MKS Instruments by sending an email to MKS or call 800-227-8766 or 978-645-5500 (outside the USA).

MKS Instruments, People's Republic of China  MKSInstruments, United Kindom  MKS Instruments, Taiwan  MKS Instruments, Germany, GmbH  MKS Instruments, Japan  MKS Instruments, France  MKS Instruments, Korea 
en español supplier support    |      MKS Logo Shop    |      privacy policy    |      legal    |      site map

© 2008 by MKS Instruments